The recommended imposed load on staircase in residential buildings as per IS 875 is:

This question was previously asked in
ESE Civil 2019 Official Paper
View all UPSC IES Papers >
  1. 5.0 kN/m2
  2. 3.0 kN/m2
  3. 1.5 kN/m2
  4. 1.3 kN/m2

Answer (Detailed Solution Below)

Option 2 : 3.0 kN/m2
Free
ST 1: UPSC ESE (IES) Civil - Building Materials
6.2 K Users
20 Questions 40 Marks 24 Mins

Detailed Solution

Download Solution PDF

As per IS 875 Part 2, clause 3.1, Imposed Floor load for residential building are:

S.No

Residential Buildings (Dwelling houses)

U.D.L (kN/m2)

1.

All rooms and kitchens

2.0

2.

Toilet and Bath rooms

2.0

3.

Corridors, passages, staircases including tire escapes and store

rooms

3.0

4.

Balconies

3.0

Latest UPSC IES Updates