For the long shunt compound generator shown in the figure, the ratio  is :

This question was previously asked in
MPPGCL JE Electrical 28 April 2023 Shift 1 Official Paper
View all MPPGCL Junior Engineer Papers >
  1. always less than 1
  2. always equal to 1
  3. always greater than 1 
  4. always equal to 0

Answer (Detailed Solution Below)

Option 1 : always less than 1
Free
MPPGCL JE Electrical Full Test 1
100 Qs. 100 Marks 120 Mins

Detailed Solution

Download Solution PDF

Concept

where, Ia = Armature current

Ish = Shunt winding current

IL = Load current

Calculation

Since the armature current (Ia) is the sum of Ish and IL

∴  Ia > IL ⇒ 

So, the ratio of  will always less than 1.